Our Priority Plus Diamond Plan includes:
$100 per year in Friendly Credits with combined coverage and
an annual Heating and Cooling Tune-Up for maximum
efficiency. No diagnostic fee for Service Calls,
PLUS repair or replacement
of the parts listed at bottom of page, at NO COST TO YOU.
| |
|
Furnace: |
- Test carbon monoxide levels.
- Clean and adjust burners and inspect heat exchanger.
- Check thermostat operation.
- Lubricate all motors, bearings, fans and circulator
pumps where possible.
- Clean pilot assembly.
- Install standard one-inch filters.
- Test and adjust operation of safety and operating
controls.
- Inspect flue pipe and gas valve.
- Check blower motor (and belt if applicable).
- Test and tighten all wiring and connections.
- Turn exposed dampers to heating position if marked
- Inform customer of equipment condition & recommend
necessary repairs.
|
|
| Hot Water Boiler: |
-
Test carbon monoxide levels.
- Check thermostat operation.
- Check electrical connections.
- Lubricate pump bearings and motors.
- Clean combustion chamber.
- Check pilot assembly.
- Check zone valves.
- Check all safeties.
- Check flue pipe and draft.
- Check expansion tank.
- Check aquastat/relay.
- Check water regulator.
|
| Steam Boiler: |
-
Test carbon monoxide levels.
- Check thermostat operation.
- Check electrical connections.
- Clean combustion chamber.
- Check pilot assembly.
- Check all safeties.
- Check flue pipe and draft.
- Check and drain low-water cutoff.
- Check gauge glass.
- Check and adjust water level.
- Check auto feed (if applicable).
|
| Master Cooling Tune-up and Safety Check |
- Lubricate all moving parts, such as blower motor &
condenser fan.
- Check suction line temperature and pressure.
- Evaluate condition of air filters. Clean or replace
with standard 1” filters.
- Test temperature drop between return and supply air.
- Flush condensate drain to protect against overflow.
- Clean the outdoor condenser coil.
- Check blower motor (and belt if applicable).
- Adjust blower speed.
- Safety test on all controls for proper operation.
- Meter voltage and amperage in all motors. Test for
worn bearings.
- Test operation and condition of compressor contacts.
- Inspect, start and run capacitors and relays for
bulges, rust and leaks.
- Tighten and safety test all wires and connections.
- Clean and adjust thermostat/mercury bulb.
- Inform customer of equipment condition. Recommend
necessary repairs
|
| The following parts will be replaced at no charge with
combined coverage: |
| |
Gas Heating System Controls
Combination Fan/Limit Control; Electronic
Ignition Control; Fan Control; Fuses; High or Low Limit
Control; Ignition Leads, Aqua stat; Thermostat |
| |
Furnace Systems/Air Handler
Blower Bearings, Blower Belts; Blower Circuit
Board, Blower Motor; Blower; Motor Capacitor, Blower Pulley;
Blower Shaft, Blower Wheel; Draft Inducer; Motor & Assembly;
Condensate Pump; Fan Relay |
| |
Boiler
Circulator Pump; Zone Valves; Expansion Tank; Low
Water Cutoff |
| |
Burner Parts
Burner Orifice; Burner Tubes; Flame Sensor;
Igniter; Gas Stop Valve; Gas Valve; Low Voltage Transformer;
Pilot Assembly; Pilot Burner; Pilot Orifice; Pilot Valve;
Pressure Regulator; Pressure Switch, Thermocouple;
Accumulator, Metering Device; Condenser Fan Blades;
Potential Relay. Condenser Fan Motor; Rain Shield;
Condensate Pump, Refrigerant. Contactor; Reversing Valve;
Crankcase Heater, Run Capacitor; Defrost Board; Thermostat;
Defrost Sensor; Starting Capacitor; Fan Belt; Starting
Relay; Fan Relay; Time Delay Board; High Pressure Control;
Low pressure Control; TXV Valve; Transformer |
| |
Friendly credits can be used
toward the purchase of the following equipment.
EZ-Flex Air Cleaner; LBP or SBP Humidifiers; Heat Recovery
Units; Complete A/C Systems; Gas Furnaces; Replacement
Condensing Units; Carrier Thermostats; Zoning Systems;
Carrier Infinity Control; Carbon Monoxide Detector; Standby
Electric Emergency Generators |